Sample Requirements
The prices provided by the FGSR are based in part on our ability to perform large numbers of assays with a minimum of manual attention. This requires that all samples we receive are appropriately concentrated for the assay to be performed. In order to continue offering these prices, any samples that do not meet the requirements listed below will be subject to a minimum sample handling fee of $10 per sample.For any questions please email us.
For QC/QA projects, submit at least 5µL per sample
| Gene Expression (total RNA) | ||
|---|---|---|
| Platform | Concentration | Volume |
| Affymetrix 3' - 1 cycle labeling 1 | 200-1500 ng/µL | 11 µL |
| Affymetrix 3' - IVT Express labeling | 40-100 ng/µL | 10 µL |
| Affymetrix Gene | 75-200 ng/µL | 6 µL |
| Affymetrix Exon (WT-Pico) | 6-25 ng/µL | 8 µL |
| Agilent | 100-500 ng/µL | 8 µL |
| Exiqon miRNA (tissue) | 500-1000 ng/µL | 5 µL |
| Exiqon miRNA (culture) | 1000-2000 ng/µL | 5 µL |
| NuGEN Amplification | 6-25 ng/µL | 8 µL |
| 1. 1 cycle labeling for Affymetrix 3' array is to be discontinuned on 12.31.2009 | ||
| Genotyping (genomic DNA)3 | ||
|---|---|---|
| Platform | Concentration | Volume |
| SNP Mapping | 50 ng/µL | 30 µL |
| Targeted Genotyping (≤ 5K)2 | 150 ng/µL | 20 µL |
| Targeted Genotyping (> 5K)2 | 150 ng/µL | 30 µL |
| Resequencing | 20 ng/µL | 25 µL |
| 2. Targeted Genotyping samples should be diluted in 1x TE | ||
| 3. All concentrations determined by PicoGreen Assay | ||
1. Prepare Your Samples
Be sure to follow the suggestions on the sample prep page when isolating. In particular, be sure that you dilute in nuclease-free water (expression samples may be diluted in the column elution buffer, eg 10mM Tris). Small numbers of samples should be in 1.5ml Eppendorf tubes. If you have more than about 20 samples, you may instead use a 96-well PCR plate. Genotyping projects should leave wells G12 and H12 empty so that we can add positive and negative controls. The plate should be sealed well with foil (Beckman, Biomek Seal & Sample, #538619).
2. Submit Your Samples Online
Log into the FGSR Project database, and select the appropriate project. Click the "Submit New Samples" button and follow the instructions on-screen (for more information, see the User's Manual).
3. Label and Drop Off
You will receive a confirmation email after submitting your samples. Print out the attached form, and use it to label your samples. Please place all samples into 1.5 ml test tubes, and clearly label each tube with the sample number (eg 228-SEL-1) shown on your order form. Mark the date of submission on the sides of the tubes, please do NOT use tape. Print the attached order sheet, and bring it with your samples to FGSR in MRB III, Room 9274 during normal business hours. Investigators outside Vanderbilt need to follow the instructions on the Shipping Samples page.